GIS02Druck

FLURO-No. GIS 02

statische Tragzahl Co kN
static load Co kN

dynamische Tragzahl
dynamic load C kN

zulässige Drehzahl
limiting speed rev/min

Stückgewicht gr. / lb.
part weight gr. / lb.

3

1,1

 

3 / 0,01

nicht nachschmierbar / without lubrication fitting
Rod Ends Series K - Requiring maintenance

Series GIS

Rod Ends with female thread regreasable through the housing with flush type grease fitting
 
Especially suited for high speed applications

 

  »  CAD Data

GIS-Drawing
Size
(D H7)
B M A F L K J O SW G GL Static load
Co kN
Dynamic load
C kN
Limiting speed
rev/min
Pivoting Angle
α (°)
Weight
g
21) 4,5 3,6 9 16 20,5 4,5 3,8 2,6 4 M 2 7 3 1,1   16 3
31) 6 4,5 14 21 28 6,5 5 5,1 5,5 M 3 10 4,1 1,8   14 6
5 8 6 18 27 36 11 9 7,7 9 M 5 10 8 3,3 1200 13 18
6 9 6,75 20 30 40 13 10 8,9 11 M 6 12 8,9 4,3 1500 13 27
8 12 9 24 36 48 16 12,5 10,4 13 M 8 16 14,1 7,1 1200 14 46
10 14 10,5 28 43 57 19 15 12,9 17 M 10 20 19,3 10 1000 13 76
12 16 12 32 50 66 22 17,5 15,4 19 M 12 22 23,5 13,5 860 13 115
14 19 13,5 36 57 75 25 20 16,8 22 M 14 25 21 17 750 16 170
16 21 15 42 64 85 27 22 19,3 22 M 16 28 32 21,5 660 15 230
18 23 16,5 46 71 94 31 25 21,8 27 M 18x1,5 32 38,5 26 600 15 320
20 25 18 50 77 102 34 27,5 24,3 32 M 20x1,5 33 44 31,5 540 14 415
22 28 20 54 84 111 37 30 25,8 32 M 22x1,5 37 53 38 500 15 540
25 31 22 60 94 124 42 33,5 29,6 36 M 24x2 42 62 47 440 15 750
30 37 25 70 110 145 51 40 34,8 41 M 30x2 51 82 64 370 17 1130
35 43 28 80 125 165 56 46 37,7 50 M 36x2 56 101 80 330 19 1600
40 49 35 90 142 187 69 57 44,2 60 M 42x2 60 124 116 290 16 2770
50 60 45 116 160 218 78 65 55,9 65 M 48x2 65 308 185 230 14 5000

 

Materials:  
Housing: Up to size 12 turned from free-cutting steel to 11SMn30+C, 12L13, galvanized
  From size 14 forged from heat-treated steel to C22, M1023, galvanized
  Size 50 turned from heat-treated steel to C45, Aisi 1045, galvanized
Insert: Special high strength bronze to CuSn8
Ball: Bearing steel to 100Cr6, Aisi 52100, hardened, ground, polished
This series is also available on request in some sizes sealed (-2RS) or with threaded bolt (-BO).
Cetop connections see G-CETOP
1) Without lubrication fitting
GA22Druck

FLURO-No. GA 22

statische Tragzahl Co kN
static load Co kN

dynamische Tragzahl
dynamic load C kN

zulässige Drehzahl
limiting speed rev/min

Stückgewicht gr. / lb.
part weight gr. / lb.

57

29

250

443 / 0,97

GA25Druck

FLURO-No. GA 25

statische Tragzahl Co kN
static load Co kN

dynamische Tragzahl
dynamic load C kN

zulässige Drehzahl
limiting speed rev/min

Stückgewicht gr. / lb.
part weight gr. / lb.

68

35

230

600 / 1,32