GIO08Druck

FLURO-No. GIO 08

statische Tragzahl Co kN
static load Co kN

dynamische Tragzahl
dynamic load C kN

zulässige Drehzahl
limiting speed rev/min

Stückgewicht gr. / lb.
part weight gr. / lb.

21,7

4,6

nicht für ganze Umdrehung geeignet
not to be used for complete revolutions

46 / 0,10

GIO06Druck

FLURO-No. GIO 06

statische Tragzahl Co kN
static load Co kN

dynamische Tragzahl
dynamic load C kN

zulässige Drehzahl
limiting speed rev/min

Stückgewicht gr. / lb.
part weight gr. / lb.

14,3

2,8

nicht für ganze Umdrehung geeignet
not to be used for complete revolutions

27 / 0,06

Rod Ends Series K - Steel on Steel

Series GIO

Rod Ends with female thread without insert
 
High axial load in one direction only
To be used only with limited oscillating movements

 

  »  CAD Data

GIO-Zeichnung
Size
(D H7)
B M A F L K J O SW G GL Static
load Co kN
Dynamic
load C kN
Limiting
speed
rev/min
Pivoting Angle
α (°)
Weight
g
5 8 6 18 27 36 11 9 7,7 9 M 5 10 12 2,2 not to be used for complete revolutions 13 18
6 9 6,75 20 30 40 13 10 8,9 11 M 6 12 14,3 2,8 13 27
8 12 9 24 36 48 16 12,5 10,5 13 M 8 16 21,7 4,6 14 46
10 14 10,5 28 43 57 19 15 12,9 17 M 10 20 27,8 6,5 13 76
12 16 12 32 50 66 22 17,5 15,4 19 M 12 22 35 8,5 13 115
14 19 13,5 36 57 75 25 20 16,8 22 M 14 25 32,5 11 16 170
16 21 15 42 64 85 27 22 19,3 22 M 16 28 46 14 15 230
20 25 18 50 77 102 34 27,5 24,3 32 M 20x1,5 33 63 20 14 415

 

Materials:  
Housing: Up to size 12 turned, from free-cutting steel to 11SMn30+C, 12L13, turned galvanized
  From size 14  forged, from heat-treated steel to C22, M1023, galvanized
Ball: Bearing steel to 100Cr6, Aisi 52100, hardened, ground, polished
Cetop connections see G-CETOP
Gelenkkopf ohne Lagerschale
The base in the steel housing is cylindrically turned from one side and, starting from the centre line, it runs to suit the ball's contour (see drawing).
Hence a high axial load towards the turned radius is possible.
achtungneu
This series is not regreasable through grease nipple.

GIO05Druck

FLURO-No. GIO 05

statische Tragzahl Co kN
static load Co kN

dynamische Tragzahl
dynamic load C kN

zulässige Drehzahl
limiting speed rev/min

Stückgewicht gr. / lb.
part weight gr. / lb.

12

2,2

nicht für ganze Umdrehung geeignet
not to be used for complete revolutions

18 / 0,04

Page 64 of 159

FLURO®-Gelenklager GmbH
Siemensstrasse 13
72348 Rosenfeld, Germany
0049 7428 / 9385-0

info[at]fluro.de

Contacts:
National / International

Newsletter:

Subscribe to our newsletter

>> Subscribe here

© 2024 FLURO®-Gelenklager GmbH
X